Some operating environments require (or at least prefer) that we do
not perform our own PCI bus scan, but deal only with specified
devices. Modularise the PCI core to allow for this.
Signed-off-by: Michael Brown <mcb30@ipxe.org>
[pci] Use single "busdevfn" field in struct pci_device
Merge the "bus" and "devfn" fields into a single "busdevfn" field, to
match the format used by the majority of external code.
Signed-off-by: Michael Brown <mcb30@ipxe.org>
On 64-bit builds, MLX_DECLARE_STRUCT() produces a structure that is
always a multiple of 64 bits long, causing the HCR structure to be
over-length by one dword. This in turn causes hermon_cmd() to write
beyond the end of the HCR, which causes commands to fail.
Reported-by: Itay Gazit <itayg@mellanox.co.il>
Signed-off-by: Michael Brown <mcb30@ipxe.org>
Avoid memory leak of untreated events by having circular event queue
operation.
Signed-off-by: Itay Gazit <itaygazit@gmail.com>
Modified-by: Michael Brown <mcb30@ipxe.org>
Signed-off-by: Michael Brown <mcb30@ipxe.org>
Remove duplicate hardware resets, remove network interface logic
reset.
This also fixes a bug where some 3c905C variants would return bogus
EEPROM values because of a too short delay after the network reset.
Signed-off-by: Thomas Miletich <thomas.miletich@gmail.com>
Reported-by: Peter Huewe <peterhuewe@gmx.de>
Tested-by: Peter Huewe <peterhuewe@gmx.de>
Signed-off-by: Michael Brown <mcb30@ipxe.org>
DBG is reserved for errors and important warnings only.
DBG2 for additional information, e.g. "received packet".
DBGP is used to print the name of every function as it is called.
Signed-off-by: Thomas Miletich<thomas.miletich@gmail.com>
Signed-off-by: Michael Brown <mcb30@ipxe.org>
Remove the concept of shutdown exit flags, and replace it with a
counter used to keep track of exposed interfaces that require devices
to remain active.
Signed-off-by: Michael Brown <mcb30@ipxe.org>
[vxge] Add support for new function mode "multi-function 8 Direct IO"
Support a new function mode "multi-function 8 Direct IO" which is used
in ESX Direct I/O configuration.
Update driver version to 3.5.0.1
Signed-off-by: Masroor Vettuparambil <masroor.vettuparambil@exar.com>
Signed-off-by: Sivakumar Subramani <sivakumar.subramani@exar.com>
Signed-off-by: Michael Brown <mcb30@ipxe.org>
[pci] Allow pci_vpd_init() return status to be ignored
Most xxx_init() functions are void functions with no failure cases.
Allow pci_vpd_init() to be used in the same way. (Subsequent calls to
pci_vpd_read() etc. will fail if pci_vpd_init() fails.)
Signed-off-by: Michael Brown <mcb30@ipxe.org>
[nvo] Remove the non-volatile options fragment list
Since its implementation several years ago, no driver has used a
fragment list containing more than a single fragment. Simplify the
NVO core and the drivers that use it by removing the whole concept of
the fragment list, and using a simple (address,length) pair instead.
Signed-off-by: Michael Brown <mcb30@ipxe.org>
[legal] Add FILE_LICENCE macro to some GPL-v2-or-later files
Changes were made to files where the licence text within the files
themselves confirms that the files are GPL version 2 or later.
Signed-off-by: Shao Miller <shao.miller@yrdsb.edu.on.ca>
Modified-by: Michael Brown <mcb30@ipxe.org>
Signed-off-by: Michael Brown <mcb30@ipxe.org>
[settings] Apply settings block name in register_settings()
Pass the settings block name as a parameter to register_settings(),
rather than defining it with settings_init() (and then possibly
changing it by directly manipulating settings->name).
Signed-off-by: Michael Brown <mcb30@ipxe.org>
[scsi] Wait for a successful TEST UNIT READY command
Some SCSI targets (observed with an EMC CLARiiON Fibre Channel target)
will not respond to commands correctly until a TEST UNIT READY has
been issued. In particular, a READ CAPACITY (10) command will return
with a success status, but no capacity data.
Fix by issuing a TEST UNIT READY command automatically, and delaying
further SCSI commands until the TEST UNIT READY has succeeded.
Reported-by: Hadar Hen Zion <hadarh@mellanox.co.il>
Signed-off-by: Michael Brown <mcb30@ipxe.org>
FCoE requires us to be able to receive unicast packets for multiple
addresses. Support this by operating in promiscuous mode.
Signed-off-by: Michael Brown <mcb30@ipxe.org>
Add PRM structures to support Hermon Ethernet devices.
Signed-off-by: Itay Gazit <itaygazit@gmail.com>
Modified-by: Michael Brown <mcb30@ipxe.org>
Signed-off-by: Michael Brown <mcb30@ipxe.org>
Unlike Arbel, port parameters must be applied via a separate call to
SET_PORT, rather than as parameters to INIT_PORT.
Signed-off-by: Michael Brown <mcb30@ipxe.org>
[hermon] Minimise the number of VPM mapping operations
Mapping a single page at a time causes a several-second delay at
device initialisation time. Reduce this by mapping multiple pages at
a time, using the largest block sizes possible given the alignment
constraints.
Signed-off-by: Michael Brown <mcb30@ipxe.org>
[arbel] Minimise the number of VPM mapping operations
Mapping a single page at a time causes a several-second delay at
device initialisation time. Reduce this by mapping multiple pages at
a time, using the largest block sizes possible given the alignment
constraints.
Signed-off-by: Michael Brown <mcb30@ipxe.org>
[arbel] Allocate only as much memory as is needed for firmware and ICM
Use individual page mappings rather than a single whole-region
mapping, to avoid the waste of memory that occurs due to the
constraint that each mapped block must be aligned on its own size.
Signed-off-by: Michael Brown <mcb30@ipxe.org>
[arbel] Synchronise changes with the Hermon driver
Backport some changes from the Hermon driver to the Arbel driver.
Specifically:
o Rename reserved_lkey to lkey
o Add arbel_rate() to calculate transmission rates
o Structure code to allow for addition of RC queue pairs
Signed-off-by: Michael Brown <mcb30@ipxe.org>
[arbel] Optimise ICM layout to reduce overall memory usage
Reduce the amount of ICM space required by choosing to order the
various allocations in approximately descending order of alignment
requirements.
This saves approximately 512kB of host memory.
Signed-off-by: Michael Brown <mcb30@ipxe.org>
[arbel] Perform ICM allocations according to the specification
The current method for ICM allocation exactly matches the addresses
chosen by the old Etherboot driver, but does not match the
specification. Some ICM tables (notably the queue pair context table)
therefore end up incorrectly aligned.
Fix by performing allocations as per the specification.
Signed-off-by: Michael Brown <mcb30@ipxe.org>